Boiler Basics 101: Emissions Rules & Regulations for San Joaquin Valley APCD
Be sure to read Part I of this series to learn about emissions requirements in the SCAQMD.
In the last edition of Boiler Blog 101, we discussed air permitting rules and regulations in the South Coast Air Quality Management District (SCAQMD). In part II, we will cover the basics of air permitting for boilers in another California district that leads the country in air pollution control; the San Joaquin Valley Air Pollution Control District (SJVAPCD).
The SJVAPCD was founded in 1991 with a mission to improve the health and quality of life for all Valley residents through efficient, effective and entrepreneurial air quality management strategies. The SJVAPCD is made up of eight counties in the Central Valley of California; San Joaquin, Stanislaus, Merced, Madera, Fresno, Kings, Tulare, and Kern.
The rules that have been set forth specifically for boilers, steam generators, and process heaters are outlined below:
QUALIFYING UNITS | NOx LIMIT | |
Rule 4306 | Units Greater Than 5 MMBtu/hr Units Greater Than 20 MMBtu/hr |
15 ppm 9 ppm |
Rule 4307 | Units 2.0 MMBtu/hr to 5.0 MMBtu/hr | 30 ppm |
Rule 4308 | Units 0.075 MMBtu/hr to Less Than 2.0 MMBtu/hr | 20 ppm |
ADVANCED EMISSION REDUCTION OPTIONS | ||
Units Greater Than 5 MMBtu/hr Units Greater Than 20 MMBtu/hr |
9 ppm 7 ppm |
|
*NOx limits listed are standard options for existing gaseous fuel-fired equipment. Enhanced options as well as limits for new and replacement units will differ. Click each rule to review the full details; certain exemptions may apply. |
Starting at the beginning of 2019, the SJVAPCD implemented a new rule titled, Best Available Control Technology (BACT). This rule requires that all new permits meet the lowest NOx limits that have been achieved, regardless of what is mandated. In addition, due to Assembly Bill 617, boiler owners in the SJVAPCD are mandated to meet Best Available Retrofit Control Technology (BARCT) for any existing equipment retrofits. This means that when your boiler needs to be upgraded or replaced, it must meet more stringent NOx limits, which can be as low as 7 ppm.
These rules can be overwhelming, which is why Nationwide Boiler’s AQMD experts are capable and ready to assist you with the permitting process needed for your facility. Furthermore, we can help you reduce NOx to comply with your air emissions regulations. Nationwide Boiler’s CataStak™ SCR system is proven to reduce NOx levels to as low as 2.5 ppm. Contact us today for more details.
Stay tuned for Part III, where we will discuss renting boilers in California.
Comments 5
Nice posts with huge information. Nowadays maximum people use the boiler in the winter season for their comfort. If you are using boiler and there is problem in it then contact the boiler repairs NJ https://allweekheating.com/boiler-repairs-nj.html company who provides the efficient and effective services of the boiler repair at the best prices. This company has years of experience.
I must thank you for the efforts you have put in penning this website.
I really hope to see the same high-grade blog posts by
you later on as well. In truth, your creative writing abilities has inspired me to get my very own blog now
Jual Hot Thermal Oil - HTO
Very good post. I just found your weblog and want to say that I really like surfing your blog posts. However I will subscribe to your rss feed and I hope you write one more time soon!Jual Pompa KSB type Etanorm
I think this is among the most important info for me. And i am glad reading your article.
But want to remark on few general things,
The site style is wonderful, the articles is really great :
D. Good job, cheers
Do you mind if I quote a few of your articles as long as I
provide credit and sources back to your weblog? My website is in the
exact same niche as yours and my visitors would really benefit from some of the information
you provide here. Please let me know if this okay with you.
Cheers!